Site Information

 Loading... Please wait...
  • OXYGEN SENSOR/ ANESTHESIA /RESPIRATORY OEM Equipment: Hudson 5577 Analyzer, Hudson 6477 Analyzer, Hudson 5590 Monitor, Hilrom 6736140, Integral Process 65003, Mercury Medical 10-103-03, Oxitron 3110, Pacifitech PT-05, Precision Medical 505325,Taema Ceasar, Teledyne R-13, Teledyne #B-39636, Teleflex Medical 5500, Maxtec Max-9, R114P80, IT Gambert M-13, MSA 655265, Sensoronics SS-05, Sensor Tec ST-05

PSR-11-55 OXYGEN SENSOR, Maxtec MAX-9

$125.00
SKU:
R114P80
Condition:
New
Shipping:
$6.00 (Fixed shipping cost)
Quantity:

Product Description

This part fits:

  • Airshields [see Hillrom]
  • Analytical Industries [PSR-11-55]
  • Hillrom (Airshields) [6736140]
  • Hudson RCI [See Teleflex Medical]
  • Integral Process [65003]
  • Maxtec [R114P80]
  • Mercury Medical [10-103-03]
  • MSA [655265]
  • Oxitron [3110]
  • Pacifitech [PT-05]
  • Precision Medical [505325]
  • Sensidyne (Maxtec) [V-05]
  • Sensor Tech [ST-05]
  • Taema [Cesar]
  • Teledyne [R13, #B-39636]
  • Teleflex Medical (Hudson RCI) [5500, V-05, 5590, 5577, 5584, 5595, 6477]

 

Specs:

Output: 26.4 to 44.0 mV
Response Time: ≤ 11 seconds
Linearity: ± 2.0% of full scale
 

 

Measuring Range

0-100%
Accuracy +2% of Full Scale
Signal Output 10-14 mV
Linearity +2% of Full Scale
Response T90 6 sec
Temp Coefficient compensated
Operating Temp 0 to 45oC
Recommended Storage 0 to 25oC
Temperature Coefficient Compensated
Shelf Life 6 months
Humidity Non-condensing 0-99% RH
Expected Life 60 months
Warranty
15 months
Electrical Conn 3 Position Nickel Gold Plated                                                                         
Measuring Range 0-100%
Accuracy +2% of Full Scale
Signal Output 10 – 14.5 mV
Linearity +2% of Full Scale
Response T90 6 sec
Temp Coefficient compensated
Operating Temp 0 to 45oC
Recommended Storage 0 to 25oC
Temperature Coefficient Compensated
Shelf Life 6 months
Humidity Non-condensing 0-99% RH
Expected Life 60 months
Warranty
12 months
Electrical Conn Modular Phone Jack                                                                         
Measuring Range 0-100%
Accuracy +2% of Full Scale
Signal Output 30.2 – 41.0 mV
Linearity +2% of Full Scale
Response T90 9 sec
Temp Coefficient  Non-compensated
Operating Temp 0 to 45oC
Recommended Storage 0 to 25oC
   
Shelf Life
6 months
Humidity Non-condensing 0-99% RH
Expected Life 60 months
Warranty
12 months
Electrical Conn 2 Ring PCB Gold Plated    

Warranty Information

12 Month